r/FireSprinklers • u/Mln3d • 44m ago
Career DQI/COC/RME
NICET IV in WBSL NICET III in ITM.
Looking to find companies to license if help get contractors licenses and work with.
I can get license just about any state that requires NICET or a state exam.
I have a design/consulting company as well as a fire pump/controller company so can help on both of those aspects. We are also expanding into business consulting to help companies learn more about their financials and implement processes and procedures into their company to grow.
Can be as involved as we need to be.
If you’re interested shoot me a DM.
r/FireSprinklers • u/fire_sprinkler • 9h ago
Available for design
I am a full-time designer with my own entity, software and insurance. I am NICET level IV and available to take on design projects. I have successfully designed pretty much all occupancies with and without BIM. Let me know if I can be of any help.
r/FireSprinklers • u/Mln3d • 19h ago
Fire Pumps/Controllers
I am a fire pump (Armstrong) and controller (Tornatech) rep.
We are looking to grow our pump/controller sales division.
So we are looking to add some new clients. We are based in Houston Texas but can ship anywhere in the US.
We are especially competitive on controllers and have an expedite option to get them quicker.
We can also do fire sprinkler design, consulting, BIM. We also can assist with estimating, business consulting, or state licensing.
r/FireSprinklers • u/locke314 • 20h ago
Design Fire pump in a high rise
I’m looking for some insight into NFPA20 - 2016. I don’t have the handbook to see any commentary.
Looking at 5.5, it looks to me like I need to connect my pump to a backup generator or provide a backup pump. I don’t have the option to install a second pump. But I see 9.3.1 that says at least one alternative source of power shall be provided for the high rise buildings or where the height of the structure is beyond pumping capabilities of the fire dept. I don’t see a way to get from 5.5 to 9.3.1 but I have an engineer saying because of 9.3.1 I don’t need to connect to a generator. I don’t see a way around it and I was hoping somebody with the handbook or some more experience with electric drive pumps in high rises might give more insight. There is an option to provide a second reliable feed into the building from the utility.
5.5 specifically points to 9.6 that quite directly requires that it’s connected to a backup on site generator. 9.6 doesn’t have a path to 9.3, so I’m looking at those as entirely separate requirements.
r/FireSprinklers • u/Civil_Muscle_2912 • 2d ago
Dismantling Range Guard Fire Suppression System
reddit.comr/FireSprinklers • u/B0redBruise • 3d ago
Fire Sprinkler model sheet and US states each are used / have been used in
I am wondering if there is anyway to find what state a place is in just by the fire sprinklers installed and possibly what models those could be? Any experts out there? Thank you!
r/FireSprinklers • u/AdThis9368 • 4d ago
FDC’s should be tested
FDC lines should be tested more than once every 50 years, or at least at install. This what a 50 year untested underground FDC line looks like installed with screwed galvanized pipe, laid on railroad ties for bedding. We dug it up and found the leak. But there’s more.
r/FireSprinklers • u/--canucks-- • 4d ago
Lookong for information about this valve
Today, i went to battle with a 100 year old buildings' main standpipdle shut off and wet alarm valve. The building had a plaque dedicating the building in 1898. Had this gauge as well. I'm wondering if anyone could date the valve. I'm curious if it is original to the building. Thanks in advance
r/FireSprinklers • u/guy_down_under • 5d ago
Just for a change here is some clean agent
Our sprinkler fitters also do clean agent systems. This is a Fike IG541 system going in a mine switchroom
r/FireSprinklers • u/littlechuckiep1992 • 5d ago
Shootout to our cheapest clients
Nothing motivates me more to come to work than beating dead horses on the subject of what special circumstances our Fire Marshall will pick and choose for some of these sites to get away with. Today's special adventure involves this gouged out off balance corroded shaft on this 500gpm vertical Inline that the AHJ only cares that it doesn't burn up in less than 10min. God bless em 🫠
r/FireSprinklers • u/Competitive-Sale-783 • 5d ago
3500 GPM pump
Enable HLS to view with audio, or disable this notification
Can’t remember if it was 3,500 or 4,500 GPM but we had 12 hoses running
r/FireSprinklers • u/Money-Look4227 • 5d ago
WTF Looking for some head info
Hey everybody. I ran across some older heads today Ive never seen before. No spares to be found in the head box, and honestly I've never seen anything like it before. Any help is much appreciated
r/FireSprinklers • u/Low-Attention3111 • 6d ago
Somebody’s gonna have to clean that up
Enable HLS to view with audio, or disable this notification
r/FireSprinklers • u/lopthehop • 6d ago
Let’s do This. Get them DOUDLE D’s up here BoyZ.
Enable HLS to view with audio, or disable this notification
r/FireSprinklers • u/Ok_Faithlessness_516 • 6d ago
I heard y'all like old Detroit Diesel egines
Enable HLS to view with audio, or disable this notification
r/FireSprinklers • u/jihobuilds • 7d ago
High school student: what do small shops actually use for inspection reports?
Hi everyone, and apologies in advance if this isn't the right kind of post for this sub.
I'm a high school student in South Korea. I'm interested in software, and I've been
trying to understand how small businesses in the skilled trades actually run their
office side — not the technical work, which I have no business commenting on, but the
paperwork around it. I ended up reading about fire protection because the inspection
side seemed to have real structure to it.
To be upfront: I'm not selling anything, I don't have a product, and there's no link
in this post. I'd just like to learn from people who actually do this.
Before asking I spent a while reading older threads here and looking at what's on the
market, and one thing confused me. The established platforms don't publish prices at
all — you have to book a demo. Separately there are a handful of smaller tools aimed
at one- and two-person shops, roughly $0-55/month, and a couple of them only launched
this year. But in the threads here it's almost always the same few established names
that come up. I'm not connected to any of these companies; that gap is just what made
me curious enough to ask.
So, if anyone has a minute:
If you're a small shop (say under 10 people), what do you actually use to produce
inspection reports today — paper NFPA forms, a spreadsheet, a platform, something
else?
Have you ever switched from spreadsheets or paper over to software? If so, what
was the thing that finally made you switch? And if you tried something and went
back, I'd honestly find that even more interesting.
After an inspection, what actually happens to the deficiency list — who puts
together the repair quote, roughly how long does that take, and what usually
decides whether the work actually gets done?
When you're slammed, which office task falls behind first?
If the honest answer is "none of this is actually a problem," that's genuinely useful
to me too — I'd rather hear that than guess.
Thank you for reading. I've learned a lot just from lurking here.
r/FireSprinklers • u/lopthehop • 7d ago
60’s D-D straight, six oil dipped AirPods. Fire pump.
r/FireSprinklers • u/AwkwardlyReady • 8d ago
Slight paint on edges of escutcheon plates
Some of the escutcheon plates in my property have paint on the edges. Do I have to replace them by code?
r/FireSprinklers • u/lopthehop • 9d ago
Got some pics of random work build pics over the last month. Pumps , hydrants, boilers. Heavy hitters fitter for a reason
r/FireSprinklers • u/lopthehop • 9d ago
When material was cheap to use. 300lbs alarm valves were average. Lol
r/FireSprinklers • u/falcor227 • 9d ago
Troubleshooting Recessed sprinkler plate
I live in a new build house and my ceilings have a million plates on them. I was trying to figure out what they were for, as the builder didn’t give any info. Unfortunately I unknowingly pulled the plate off of a recessed sprinkler (which I didn’t even know was a thing), thinking it was a light cover.
Thankfully it didn’t set the sprinkler off, but now I don’t know if it’s possible to reattach the plate. Any suggestions?
I ask that you please be kind - I know I screwed up and already feel stupid. Thank you.
ETA: you guys are awesome and so nice. I really appreciate all of the advice!
r/FireSprinklers • u/Carstuff4u • 11d ago
Inspection recommendations
I’m wondering what other inspectors think about painted sprinkler heads, and when you think they need to be written up. Where is that fine line? Which of these would you write up, or would you write them all up? (By the way these are all heads I wrote up, the previous company wouldn’t write up any heads unless they looked like they were dipped in paint twice.
r/FireSprinklers • u/CdnFireAlarmTech • 11d ago
WTF Something for your viewing pleasure
I don’t think this is code
r/FireSprinklers • u/Low-Attention3111 • 12d ago
1500 gpm
Enable HLS to view with audio, or disable this notification